Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Am Heart J ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38701961

RESUMO

BACKGROUND: There has not been a consensus on the prothesis sizing strategy in type 0 bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR). Modifications to standard annular sizing strategies might be required due to the distinct anatomical characteristics. We have devised a Down Sizing Strategy for TAVR using a self-expanding valve specifically for patients with type 0 bicuspid AS. The primary aim of this study is to compare the safety and efficacy of Down Sizing Strategy with the Standard Annulus Sizing Strategy in TAVR for patients with type 0 bicuspid AS. TRIAL DESIGN: It is a prospective, multi-center, superiority, single-blinded, randomized controlled trial comparing the Down Sizing and Standard Annulus Sizing Strategy in patients with type 0 bicuspid aortic stenosis undergoing transcatheter aortic valve replacement. Eligible participants will include patients with severe type 0 bicuspid AS, as defined by criteria such as mean gradient across aortic valve ≥40 mmHg, peak aortic jet velocity ≥4.0 m/s, aortic valve area (AVA) ≤1.0 cm², or AVA index ≤0.6 cm2/m2. These patients will be randomly assigned, in a 1:1 ratio, to either the Down Sizing Strategy group or the Standard Sizing Strategy group. In the Down Sizing Strategy group, a valve one size smaller will be implanted if the "waist sign" manifests along with less than mild regurgitation during balloon pre-dilatation. The primary end point of the study is a composite of VARC-3 defined device success, absence of both permanent pacemaker implantation due to high-degree atrioventricular block and new-onset complete left bundle branch block. CONCLUSION: This study will compare the safety and efficacy of Down Sizing Strategy with the Standard Annulus Sizing Strategy and provide valuable insights into the optimal approach for sizing in TAVR patients with type 0 bicuspid AS. We hypothesize that the Down Sizing Strategy will demonstrate superiority when compared to the Standard Annulus Sizing Strategy. (Down Sizing Strategy (HANGZHOU Solution) vs Standard Sizing Strategy TAVR in Bicuspid Aortic Stenosis (Type 0) (TAILOR-TAVR), NCT05511792).

2.
Chem Res Toxicol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634348

RESUMO

Acrylamide (ACR) is a common industrial contaminant with endocrine-disrupting toxicity. Numerous studies have indicated that females and diabetics are more sensitive to environmental contaminants. However, it remains unknown whether female diabetics are susceptible to ACR-induced toxicity and its potential mechanisms. Thus, the female ACR-exposure diabetic Balb/c mice model was established to address these issues. Results showed that ACR could induce liver injury in normal mice and cause more serious inflammatory cell infiltration, hepatocyte volume increase, and fusion in diabetic mice liver. Meanwhile, ACR could lead to exacerbation of diabetic symptoms in diabetic mice by disturbing the glucose and lipid metabolism in the liver, which mainly manifests as the accumulation of liver glycogen and liver lipids, the reduction of the activity/content of glycolytic and metabolizing enzyme as well as pentose phosphatase, upregulation of the gene expression in fatty acid transporter and gluconeogenesis, and downregulation of the gene expression in fatty acid synthesis and metabolism. Moreover, ACR exposure could induce oxidative stress, inflammation, and endoplasmic reticulum stress in the liver by a decrease in hepatic antioxidant enzyme activity and antioxidant content, an increase in inflammatory factor levels, and a change in the related protein expression of endoplasmic reticulum stress (ERS) and apoptosis-related pathways in diabetic mice. Statistical analysis results revealed that ACR-induced liver injury was highly correlated with inflammation and oxidative stress, and ERS and diabetic mice had a higher risk of liver injury than normal mice. Overall results suggested that female diabetic mice easily suffer from ACR-induced toxicity, and the reason was that ACR could induce further damage to the liver by worsening the condition of inflammation, oxidative stress, and ERS in the liver.

3.
Toxicology ; 504: 153800, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38604440

RESUMO

Acrylamide (ACR) is an endogenous food contaminant, high levels of ACR have been detected in a large number of foods, causing widespread concern. Since different organism states respond differently to the toxic effects of pollutants, this study establishes an insulin-resistant BRL cell model to explore the differential susceptibility of BRL cells with/without insulin resistance in response to acrylamide-exposure (0.0002, 0.02, or 1 mM) toxicity effects and its mechanism. The results showed that ACR exposure decreased glucose uptake and increased intracellular lipid levels by promoting the expression of fatty acid synthesis, transport, and gluconeogenesis genes and inhibiting the expression of fatty acid metabolism genes, thereby further exacerbating disorders of gluconeogenesis and lipid metabolism in insulin-resistant BRL cells. Simultaneously, its exposure also exacerbated BRL cells with/without insulin-resistant damage. Meanwhile, insulin resistance significantly raised susceptibility to BRL cell response to ACR-induced toxicity. Furthermore, ACR exposure further activated the endoplasmic reticulum stress (ERS) signaling pathway (promoting phosphorylation of PERK, eIF-2α, and IRE-1α) and the apoptosis signaling pathway (activating Caspase-3 and increasing the Bax/Bcl-2 ratio) in BRL cells with insulin-resistant, which were also attenuated after ROS scavenging or ERS signaling pathway blockade. Overall results suggested that ACR evokes a severer toxicity effect on BRL cells with insulin resistance through the overactivation of the ERS signaling pathway.


Assuntos
Acrilamida , Estresse do Retículo Endoplasmático , Resistência à Insulina , Transdução de Sinais , Animais , Ratos , Acrilamida/toxicidade , Apoptose/efeitos dos fármacos , Linhagem Celular , Estresse do Retículo Endoplasmático/efeitos dos fármacos , Glucose/metabolismo , Metabolismo dos Lipídeos/efeitos dos fármacos , Espécies Reativas de Oxigênio/metabolismo , Transdução de Sinais/efeitos dos fármacos
4.
Circ Cardiovasc Qual Outcomes ; 17(1): e010066, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38088154

RESUMO

BACKGROUND: This study aims to evaluate limited data about daily physical activity patterns, influential factors, and their association with 1-year mortality or rehospitalization after transcatheter aortic valve replacement (TAVR) through smartwatches. METHODS: Consecutive severe aortic stenosis patients undergoing elective transfemoral TAVR in a Chinese tertiary hospital were enrolled from July 2021 to May 2022 and received a Huawei smartwatch at least 1 day before TAVR. The primary outcome was a composite of all-cause mortality or hospital readmission within 1 year. Linear mixed-effects models were applied to determine influential factors of daily step counts, and Cox proportional hazard regression models were to estimate the association between baseline step counts within 1 month since discharge and composite outcome from months 2 to 12. The dose-response association was assessed using restricted cubic spline curves. RESULTS: A total of 222 participants and 59 469 valid monitoring person-day records were included (mean age, 72.7 years; 61% women). Step counts increased rapidly within the first 2 months (P<0.001), followed by a slower increase for those without composite outcomes (P=0.029) and a gradual decrease for those who developed composite outcomes (P<0.001). In multivariate linear mixed models, a 1-m increase in baseline 6-minute walk test and a 1-month delay after discharge were associated with 4 (95% CI, 1-7) and 170 (95% CI, 145-194) additional step counts, respectively. In restricted cubic spline analysis, the hazard ratio declined progressively until ≈5000 steps per day, after which they leveled. Below 5000 steps, the adjusted hazard ratio of composite outcome associated with each 1000-step count increase was 0.67 (0.50-0.89; P=0.007). However, above 5000 steps, step counts were not significantly associated with the composite outcome (P=0.645), with a hazard ratio of 1.12 (0.70-1.79). CONCLUSIONS: Daily step counts rapidly increased within the first 2 months post-TAVR. Increased physical activity was associated with a lower risk of 1-year mortality or rehospitalization after TAVR for patients with daily step counts below 5000. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04454177.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos Eletrônicos Vestíveis , Humanos , Feminino , Idoso , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Exercício Físico , Valva Aórtica/cirurgia , Fatores de Risco , Índice de Gravidade de Doença
5.
Nanoscale ; 15(31): 12961-12971, 2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37462542

RESUMO

Lithium-sulfur (Li-S) batteries are severely restricted for practical application due to the polysulfide shuttle effect, Li dendrites and thermal runaway. The use of PEO-based polymer composite electrolytes (PCEs) as an alternative strategy suffers from limited lithium-ion conductivity with deficient long-range transfer route. Herein, Li6.4La3Zr1.4Ta0.6O12 (LLZTO) nanoparticles modified with an in situ-synthesized zwitterionic covalent organic framework layer (denoted as LLZTO@HUT4) were introduced into PEO-based PCEs. Zwitterionic HUT4 modified the lithiophobic LiOH/Li2CO3 layer on the surface of LLZTO nanoparticles, which could notably promote Li+ ion transport for superior electrochemical performance of PCEs. Additionally, the intermediate layer HUT4 located between LLZTO and PEO could further improve the mechanical properties of electrolytes due to the enhanced inorganic/organic interface compatibility and intermolecular interaction. As a result, the obtained LLZTO@HUT4-15%/PEO electrolyte exhibited a competent ionic conductivity of 0.73 mS cm-1 with a Li+ transference number of up to 0.74 at 60 °C. The assembled S@CNT|LLZTO@HUT4-15%/PEO|Li coin cell delivered a considerable initial discharge capacity of 1018 mA h g-1 at 0.2 C, with approximately 92.1% capacity retention after 100 cycles, elucidating an obviously suppressed shuttle effect.

6.
RSC Adv ; 13(27): 18488-18495, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37346941

RESUMO

The investigation of cost-effective, highly efficient, and environmentally friendly non-noble-metal-based electrocatalysts is imperative for oxygen evolution reactions (OER). Herein, CoV2O6 grown on nickel foam (NF) was selected as the fundamental material, and Fe2+ is introduced through a simple Fe3+ immersion treatment to synthesize CoV2O6-Fe-NF. Fe2+ is transformed into high oxidation state Fe(2+δ)+ due to interactions between the 3d electrons of transition metals. In situ Raman spectroscopy analysis reveals the specific process of OER in the presence of Fe(2+δ)+. Being in a higher oxidation state, Fe(2+δ)+ provides more active sites, which is beneficial for the reaction between water molecules and the reactive sites of the electrocatalyst, ultimately enhancing the accelerated OER process. CoV2O6-Fe-NF exhibited an overpotential of only 298 mV at 100 mA cm-2 in 1 M KOH electrolyte, which is lower than that of CoV2O6-NF (348 mV), as well as the comparative samples: Fe-NF (390 mV) and NF (570 mV). The exploration of high performance, triggered synergistically by the cooperative effect of transition metal 3d electrons, provides insights into the design of transition metal electrocatalysts for highly efficient OER.

7.
J Clin Med ; 12(2)2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36675336

RESUMO

Objective: Trimethylamine N-oxide (TMAO), a pathological microbial metabolite, is demonstrated to be related to cardiovascular diseases. This study was (1) to investigate the association between TMAO and aortic stenosis and (2) to determine the prognostic value of TMAO for predicting mortality after transcatheter aortic valve replacement (TAVR). Methods: 299 consecutive patients (77 (72−81) years, 58.2% male, Society of Thoracic Surgeons (STS) score 5.8 (4.9−9.3)) with severe aortic stenosis and 711 patients (59 (52−66) years, 51.9% male) without aortic stenosis were included in this retrospective study. A total of 126 pairs of patients were assembled by Propensity Score Matching. The primary outcome was all-cause mortality using survival analyses stratified by TMAO quartiles. Results: Patients with severe aortic stenosis had higher TMAO levels (3.18 (1.77−6.91) µmol/L vs. 1.78 (1.14−2.68) µmol/L, p < 0.001), and TMAO remained significantly higher after adjusting for baseline characteristics. Higher TMAO level was associated with higher 2-year all-cause mortality (19.2% vs. 9.5%, log-rank p = 0.028) and higher late cumulative mortality (34.2% vs. 19.1%, log-rank p = 0.004). In Cox regression multivariate analysis, higher TMAO level remained an independent predictor (hazard ratio 1.788; 95% CI 1.064−3.005, p = 0.028) of all-cause mortality after adjusting for STS score, N-terminal pro b-type natriuretic peptide, and maximum velocity. Conclusions: The TMAO level was higher in aortic stenosis patients. Elevated TMAO was associated with poor adverse outcome after TAVR.

8.
J Cardiovasc Transl Res ; 16(2): 443-452, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36223050

RESUMO

Irisin, a myokine mainly secreted by skeletal and cardiac muscles, is actively involved in cardiovascular diseases. However, whether irisin is associated with aortic stenosis remains unknown. Two hundred ninety-three severe AS patients who underwent transcatheter aortic valve implantation were enrolled and followed-up for 35 months on average. Enzyme-linked immunosorbent assay (ELISA) was applied to measure circulating irisin levels. Patients were divided into two groups based on the median plasma irisin level. We found that high plasma irisin levels were independently associated with pure aortic stenosis (PAS) after adjusting for age, body mass index, history of peripheral vascular disease, and creatinine (OR = 3.015, 95% CI 1.775-5.119, P < 0.001). ROC curve analysis showed a significant predictive value of irisin for PAS (AUC = 0.647, 95% CI 0.583-0.711, P < 0.001). The severity of aortic valve calcification was negatively associated with plasma irisin levels (P < 0.05). In conclusion, irisin is an independent predictor for PAS and is negatively associated with the severity of aortic valve calcification.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Humanos , Fibronectinas , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Biomarcadores , Índice de Gravidade de Doença
9.
J Clin Med ; 11(21)2022 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-36362730

RESUMO

Evidence for transcatheter aortic valve implantation (TAVI) is scarce among patients with non-calcific aortic stenosis, and it is not known whether aortic valve calcification is associated with new cerebral ischemic lesions (CILs) that are detected by diffusion-weighted magnetic resonance imaging. So, our study enrolled 328 patients who underwent transfemoral TAVI using a self-expanding valve between December 2016 and June 2021 from the TORCH registry (NCT02803294). A total of 34 patients were finally confirmed as non-calcific AS and the remaining 294 patients were included in the calcific AS group. Incidence of new CILs (70.6% vs. 85.7%, p = 0.022), number of lesions (2.0 vs. 3.0, p = 0.010), and lesions volume (105.0 mm3 vs. 200.0 mm3, p = 0.047) was significantly lower in the non-calcific AS group. However, the maximum and average lesion volumes were comparable between two groups. Non-calcific AS was associated with lower risk for developing new CILs by univariate logistic regression analysis [Odds ratio (OR): 0.040, 95% confident interval (CI): 0.18-0.90, p = 0.026] and multivariate analysis (OR: 0.031, 95% CI: 0.13-0.76, p = 0.010). In summary, non-calcific AS patients had a lower risk of developing new cerebral ischemic infarction after TAVI compared to calcific AS patients. However, new ischemic lesions were still found in over 70% of patients.

10.
Int J Cardiol Heart Vasc ; 42: 101101, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35937949

RESUMO

Background: Decreased length of stay in the index hospitalization is a tendency in transcatheter aortic valve replacement (TAVR) era. In this study, we aim to evaluate the feasibility and safety of next-day discharge (NDD) in bicuspid aortic valve (BAV) patients following TAVR. Methods: The study analyzed patients who received TAVR in 2019 to 2022. Thirty-day mortality and readmission rate were compared between BAV and tricuspid aortic valve (TAV) patients. Results: The proportion of NDD was similar between the BAV and TAV group (45.3 % vs 41.3 %, p = 0.487). In NDD patients, the lower age (72.0 [67.0, 77.0] yrs vs 74.0 [70.0, 80.0] yrs, p = 0.011) and STS score (2.33 [1.56, 3.54] % vs 3.82 [2.38, 5.70] %, p < 0.001) were observed in the BAV group. The NDD BAV patients had higher proportion of post-dilatation (74.3 % vs 50.7 %, p = 0.003) when compared with the TAV patients. The NDD patients was safe with no death both in BAV and TAV patients at 30-day follow-up. Moreover, the readmission rate was comparable between BAV and TAV patients who discharged on the next day after TAVR (8.1 % vs 14.0 %, p = 0.397). Conclusions: NDD after TAVR was feasible and safe in both BAV and TAV patients. The younger BAV patients with fast recovery deserve the next-day discharge after TAVR.

11.
BMC Cardiovasc Disord ; 22(1): 164, 2022 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-35413789

RESUMO

BACKGROUND: Unlike N-terminal pro-B-type natriuretic peptide (NT-proBNP), which have been extensively studied, little is known about the role of N-terminal pro-C-type natriuretic peptide (NT-proCNP) for predicting survival post transcatheter aortic valve replacement (TAVR). METHODS: A total of 309 patients were included in the analysis. Patients were grouped into quartiles (Q1-4) according to the baseline NT-proCNP value. Blood for NT-proCNP analysis was obtained prior to TAVR procedure. The primary endpoint was mortality after a median follow-up of 32 months. Multivariable Cox proportional hazards regression models analyzed prognostic factors. The predictive capability was compared between NT-proBNP and NT-proCNP using receiver operator curve (ROC) analysis. RESULTS: A total of 309 subjects with the mean age of 76.8 ± 6.3 years, among whom 58.6% were male, were included in the analysis. A total of 58 (18.8%) patients died during follow-up. Cox multivariable analyses indicated society of thoracic surgeons (STS)-score was a strong independent predictor for mortality (hazard ratio (HR) 1.08, 95% confidential interval (CI) 1.05-1.12, P < 0.001). Elevated NT-proCNP was associated with a higher risk of cardiovascular mortality (HR 1.02, 95% CI 1.00-1.03, P = 0.025) and All-cause mortality (HR 1.01, 95% CI 1.00-1.03, P = 0.027), whereas NT-proBNP showed a small effect size on mortality. ROC analysis indicated that NT-proCNP was superior to NT-proBNP for TAVR risk evaluation in patients with left ventricular ejection fraction (LVEF) < 50% [(Area under the curve (AUC)-values of 0.79 (0.69; 0.87) vs. 0.59 (0.48; 0.69), P = 0.0453]. CONCLUSIONS: NT-proCNP and STS-Score were the independent prognostic factors of mortality among TAVR patients. Furthermore, NT-proCNP was superior to NT-proBNP for TAVR risk evaluation in patients with LVEF < 50%. Trial registration NCT02803294, 16/06/2016.


Assuntos
Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Biomarcadores , Diuréticos , Humanos , Masculino , Peptídeo Natriurético Encefálico , Peptídeo Natriurético Tipo C , Fragmentos de Peptídeos , Prognóstico , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Vasodilatadores , Função Ventricular Esquerda
12.
J Am Heart Assoc ; 11(7): e023219, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35347997

RESUMO

Background In the recent decades, the development of novel digital health technologies enables doctors to monitor ECG and vital signs remotely. But the data on applying the noninvasive wearable smartwatch on patients with transcatheter aortic valve replacement (TAVR) are unknown. Methods and Results We performed a prospective, observational cohort study to evaluate the feasibility of a novel, virtual, and remote health care strategy for patients with TAVR discharged to home with smart wearable devices. A total of 100 consecutive patients with severe aortic stenosis who underwent elective transfemoral TAVR were enrolled and received the Huawei smartwatch at least 1 day before TAVR. Vital signs, including heart rate, rhythm, oxygen saturation, and activity, were continuously recorded. Single-lead ECG was recorded twice per day in the week following TAVR discharge and at least 2 days a week for the subsequent month after TAVR discharge. A designated heart team member provided remote health care with the data from the smartwatch when the patient had a need. Thirty-eight cardiac events were reported in 34 patients after discharge, with most of the events (76.0%) detected and confirmed by the smartwatch. Six patients were advised and readmitted to the hospital for arrhythmia events detected by the smartwatch, of whom 4 patients received pacemaker implantation. The remaining 28 (82.4%) patients received telemedicine monitoring instead of face-to-face clinical visits, and 3 of them received new medication treatment under the online guidance of doctors. New-onset left branch bundle block was found in 48 patients, with transient characteristics, and recovered spontaneously in 30 patients, and new-onset atrial fibrillation was detected in 4 patients. There were no significant differences in the average weekly heart rates or the ratio of abnormal or low oxygen saturation when compared with the baseline. The average daily steps increased over time significantly (baseline, 870±1353 steps; first week, 1986±2406 steps; second week, 2707±2716 steps; third week, 3059±3036 steps; fourth week, 3678±3485 steps, P<0.001). Conclusions Smartwatches can facilitate remote health care for patients discharged to home after undergoing TAVR and enable a novel remote follow-up strategy. The majority of cardiac clinical events that occurred within 30-day follow-up were detected by the smartwatch, mainly because of the record of conduction abnormality. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT04454177.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos Eletrônicos Vestíveis , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 99 Suppl 1: 1482-1489, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35324060

RESUMO

OBJECTIVES: We aimed to validate a novel staging system for aortic stenosis (AS) in a Chinese patient cohort undergoing transcatheter aortic valve replacement (TAVR), and to compare this classification system to the traditional Society of Thoracic Surgeons (STS) score for TAVR risk stratification. BACKGROUND: A novel staging system for AS based on the extent of cardiac damage upon echocardiography was recently proposed. METHODS: Patients were prospectively enrolled into the Transcatheter Aortic Valve Replacement Single Center Registry in Chinese Population and analyzed retrospectively following additional exclusion criteria. On the basis of echocardiographic findings of cardiac damage, patients were classified into five stages (0-4). RESULTS: A total of 427 patients were included in the current analysis. Forty-eight deaths occurred during a median follow-up of 730 days following TAVR. The staging system showed a statistically significant association between cardiac damage and all-cause mortality; advanced stages were associated with higher mortality. In a multivariate-adjusted Cox proportional hazards regression model, stage and STS scores served as risk factors for 2-year mortality. Each increment in the staging class was associated with an increased risk of mortality (hazard ratio, 1.275; 95% confidence interval [CI], 1.052-1.545). Receiver operating characteristic (ROC) curves were plotted for stage (area under the curve, 0.644; 95% CI, 0.562-0.725) and STS score (0.661; 0.573-0.749), and with no statistically significant differences between ROC curves (p = 0.920). CONCLUSIONS: We validated a novel staging system as a key risk factor for 2-year mortality in a Chinese TAVR patient cohort. Efficacy for risk stratification was comparable to the STS score.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , China , Humanos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
EuroIntervention ; 18(3): 193-202, 2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35044300

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) might be a feasible treatment option for more patients with bicuspid aortic valve (BAV) stenosis. However, long-term follow-up data in this population are scarce. AIMS: The aim of this study was to evaluate three-year outcomes after TAVI in patients with BAV. METHODS: A total of 246 consecutive patients who underwent TAVI at a single centre in China between March 2013 and February 2018 were enrolled in this study. Clinical outcomes, health status and echocardiography were followed and recorded for three years. RESULTS: Among 109 (44.3%) BAV patients, 61.5% were Type 0 and 36.7% were Type 1 BAV patients. BAV patients were younger (75 vs 77 years, p=0.041) and had a lower Society of Thoracic Surgeons (STS) score (5.09 vs 6.00, p=0.026) compared to tricuspid aortic valve (TAV) patients. There were no differences in three-year survival rates between bicuspid and tricuspid patients (87.1% vs 79.5%, log-rank p=0.126). Multivariate Cox regression analysis adjusting for confounding factors revealed a similar risk of all-cause mortality in the BAV population (hazard ratio [HR] 0.86, 95% confidence interval [CI]: 0.44-1.70, p=0.666). Except for the rate of permanent pacemaker implantation that was lower in BAV patients (11.9% vs 21.9%, p=0.041), the incidence of other clinical adverse events was comparable between the two groups. Both BAV and TAV patients showed an obvious improvement in valve haemodynamics, which was sustained for three years. In addition, similar left ventricular reverse remodelling was found during follow-up. CONCLUSIONS: BAV patients showed similar satisfactory three-year clinical outcomes, persistent valve haemodynamics improvement, and obvious cardiac reverse remodelling after TAVI compared to TAV patients.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Estenose da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Remodelação Ventricular
15.
Catheter Cardiovasc Interv ; 99 Suppl 1: 1432-1439, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35094487

RESUMO

OBJECTIVES: To evaluate the feasibility of self-expanding transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis and extremely horizontal aortas (aortic angulation ≥70°). BACKGROUND: As TAVR using a self-expanding prosthesis is an off-label treatment for patients with extremely horizontal aortas, these patients are often excluded from randomized controlled trials involving self-expanding TAVR. METHODS: This study enrolled 27 consecutive patients with extremely horizontal aortas who underwent self-expanding TAVR for severe aortic stenosis. RESULTS: The patients' average age was 76.4 years, with a median Society of Thoracic Surgeons score of 4.53%. The device success and 30-day mortality rates were 66.7% and 7.4%, respectively. The sinotubular junction (STJ) was significantly smaller in the device success group (p = 0.001). The receiver operating characteristic curve analysis found that the area under the curve was 0.907 (95% confidence interval: 0.790-1.000, p = 0.001), validating the association between STJ diameter and device success. An optimal cutoff of 33.6 mm was determined using the Youden index, with a sensitivity and specificity of 88.9% and 77.8%, respectively. The device success rate was significantly higher (93.3% vs. 33.3%, p = 0.003) in patients with STJ diameters ≤33.6 mm (n = 15). In the subgroup analyses, severe valve calcification (n = 9) was associated with a higher incidence of moderate or severe paravalvular leakage (44.0% vs. 0%, p = 0.008), while a higher rate of second valve implantation (60.0% vs. 9.1%, p = 0.030) was found in patients with less than moderate valve calcification (n = 5). CONCLUSION: Self-expanding TAVR could be suitable for patients with extremely horizontal aortas after careful preoperative evaluation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
16.
Toxicol Lett ; 356: 41-53, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34896238

RESUMO

Diabetes mellitus is a common endocrine metabolic disorder, and previous studies have shown that diabetics are more sensitive to the toxic environmental contaminants. Acrylamide (ACR) is both an industrially multipurpose compound and a common endogenous food contaminant to which people are frequently exposed and at high risk. However, the toxicity of ACR on diabetes hasn't attracted much attention. In this study, both healthy mice and diabetic mice received ACR administration orally to investigate the ACR-induced metabolic toxicity, mechanism and susceptibility to ACR toxicity in adult diabetic male mice. The results showed that ACR significantly increased FBG level and decreased bodyweight, serum lipid and liver lipid biomarkers (TC, TG, LDL-C, HDL-C) levels as well as expression of lipid and glucose metabolism-related genes in diabetic mice, indicating that ACR can exacerbate metabolic disorders of glucose and lipid in diabetic male mice. Moreover, ACR exposure significantly increased levels of MDA and COX-2), decreased GSH level and antioxidant enzyme activity (SOD, GSH-PX and CAT) by downregulating expression of Nrf2 and Keap1 in diabetic mice. Factorial analysis showed ACR had a more significant disturbance in diabetic mice compared with healthy mice. Our results indicated that ACR exposure can cause oxidative stress and inflammatory damage, which can exacerbate abnormal glucose and lipid metabolism. This work helps to elucidate the effects and underlying mechanisms of ACR-induced metabolic toxicity in adults with diabetes.


Assuntos
Acrilamida/toxicidade , Diabetes Mellitus Experimental/complicações , Inflamação/induzido quimicamente , Doenças Metabólicas/induzido quimicamente , Doenças Metabólicas/complicações , Estresse Oxidativo/efeitos dos fármacos , Animais , Poluentes Ambientais/toxicidade , Ácidos Graxos , Regulação da Expressão Gênica/efeitos dos fármacos , Masculino , Camundongos , Análise de Componente Principal , Distribuição Aleatória
17.
Front Cardiovasc Med ; 8: 757190, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34912864

RESUMO

Objective: To evaluate the predictors of new-onset conduction disturbances in bicuspid aortic valve patients using self-expanding valve and identify modifiable technical factors. Background: New-onset conduction disturbances (NOCDs), including complete left bundle branch block and high-grade atrioventricular block, remain the most common complication after transcatheter aortic valve replacement (TAVR). Methods: A total of 209 consecutive bicuspid patients who underwent self-expanding TAVR in 5 centers in China were enrolled from February 2016 to September 2020. The optimal cut-offs in this study were generated from receiver operator characteristic curve analyses. The infra-annular and coronal membranous septum (MS) length was measured in preoperative computed tomography. MSID was calculated by subtracting implantation depth measure on postoperative computed tomography from infra-annular MS or coronal MS length. Results: Forty-two (20.1%) patients developed complete left bundle branch block and 21 (10.0%) patients developed high-grade atrioventricular block after TAVR, while 61 (29.2%) patients developed NOCDs. Coronal MS <4.9 mm (OR: 3.08, 95% CI: 1.63-5.82, p = 0.001) or infra-annular MS <3.7 mm (OR: 2.18, 95% CI: 1.04-4.56, p = 0.038) and left ventricular outflow tract perimeter <66.8 mm (OR: 4.95 95% CI: 1.59-15.45, p = 0.006) were powerful predictors of NOCDs. The multivariate model including age >73 years (OR: 2.26, 95% CI: 1.17-4.36, p = 0.015), Δcoronal MSID <1.8 mm (OR: 7.87, 95% CI: 2.84-21.77, p < 0.001) and prosthesis oversizing ratio on left ventricular outflow tract >3.2% (OR: 3.42, 95% CI: 1.74-6.72, p < 0.001) showed best predictive value of NOCDs, with c-statistic = 0.768 (95% CI: 0.699-0.837, p < 0.001). The incidence of NOCDs was much lower (7.5 vs. 55.2%, p < 0.001) in patients without Δcoronal MSID <1.8 mm and prosthesis oversizing ratio on left ventricular outflow tract >3.2% compared with patients who had these two risk factors. Conclusion: The risk of NOCDs in bicuspid aortic stenosis patients could be evaluated based on MS length and prosthesis oversizing ratio. Implantation depth guided by MS length and reducing the oversizing ratio might be a feasible strategy for heavily calcified bicuspid patients with short MS.

18.
Front Cardiovasc Med ; 8: 732784, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34708088

RESUMO

Background: Patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) can provide unique insights in device-patient interaction. Aims: This study was to compare transcatheter aortic valve sealing behavior in patients with bicuspid aortic valves (BAV) and tricuspid aortic valves (TAV) through patient-specific computational modeling. Methods: Patient-specific computer simulation was retrospectively performed with FEops HEARTguide for TAVR patients. Simulation output was compared with postprocedural computed tomography and echocardiography to validate the accuracy. Skirt malapposition was defined by a distance larger than 1 mm based on the predicted device-patient interaction by quantifying the distance between the transcatheter heart valve (THV) skirt and the surrounding anatomical regions. Results: In total, 43 patients were included in the study. Predicted and observed THV frame deformation showed good correlation (R 2 ≥ 0.90) for all analyzed measurements (maximum diameter, minimum diameter, area, and perimeter). The amount of predicted THV skirt malapposition was strongly linked with the echocardiographic grading of paravalvular leakage (PVL). More THV skirt malapposition was observed for BAV cases when compared to TAV cases (22.7 vs. 15.5%, p < 0.05). A detailed analysis of skirt malapposition showed a higher degree of malapposition in the interleaflet triangles section for BAV cases as compared to TAV patients (11.1 vs. 5.8%, p < 0.05). Conclusions: Patient-specific computer simulation of TAVR can accurately predict the behavior of the Venus A-valve. BAV patients are associated with more malapposition of the THV skirt as compared to TAV patients, and this is mainly driven by more malapposition in the interleaflet triangle region.

20.
Carbohydr Polym ; 258: 117380, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33593586

RESUMO

A new polysaccharide from fruits of Schisandra chinensis (SCPP22) with a molecular weight of 143 ± 0.13 KDa was mainly made up of glucose and galactose. The possible structure of SCPP22 was showed that its main chain was composed of 1,4-α-d-Glup and branch was stretched from O-6 position of 1,4-ß-d-Glup. Branches consisted of T-α-d-Galp. Further, SCPP22 could reverse PCB126-induced immunosuppression, significantly enhance body weight and immune organ indices. It also significantly ameliorated oxidative injury to immune organ induced by PCB126, as shown by evaluation of SOD activities, as well as MDA levels in spleen and thymus. SCPP22 strongly stimulated cytokines production by up-regulating mRNA expression of TNF-α, INF-γ and IL-2. Mechanism investigation revealed that recovery effects of SCPP22 in immunosuppression induced by PCB126 are mainly through regulating apoptosis-related proteins expression. Schisandra polysaccharides might be applied in functional food as nutritional intervention ingredient.


Assuntos
Glucanos/química , Bifenilos Policlorados/química , Polissacarídeos/química , Schisandra/metabolismo , Animais , Peso Corporal , Feminino , Sistema Imunitário , Terapia de Imunossupressão , Espectroscopia de Ressonância Magnética , Masculino , Malondialdeído/metabolismo , Camundongos , Camundongos Endogâmicos ICR , Monossacarídeos/química , Estresse Oxidativo/efeitos dos fármacos , Espectroscopia de Infravermelho com Transformada de Fourier , Baço/efeitos dos fármacos , Timo/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA